34.2.
List of Parameters C008 to C128
Table 78: List of parameters C008 to C128
Parameter
FUNCTION
User Level
MODBUS
Address
DEFAULT
VALUES
C008
Rated mains voltage
BASIC
1008
2:[380
÷
480V]
C009
N. of configured motors
ENGINEERING
1009
1
Parameter
FUNCTION
User Level
MODBUS
Address
DEFAULT
VALUES
C010
M1
Type of control algorithm
BASIC
1010
0: IFD
C053
M2
1053
C096
M3
1096
C011
M1
Type of reference
ADVANCED
1011 bit 0
0: Speed (MASTER mode)
C054
M2
1054 bit 0
C097
M3
1097 bit 0
C011c M1
Torque Follower mode
BASIC
1012 bit 1
0: No
C054c M2
1055 bit 1
C097c M3
1098 bit 1
C012
M1
Speed feedback from encoder
BASIC
1012
0: No
C055
M2
1055
C098
M3
1098
C013
M1
Type of V/f curve
BASIC
1013
C056
M2
1056
C099
M3
1099
C014
M1
Phase rotation
ENGINEERING
1014
0: No
C057
M2
1057
C100
M3
1100
C015
M1
Rated motor frequency
BASIC
1015
50.0 Hz
C058
M2
1058
C101
M3
1101
C016
M1
Rated motor rpm
BASIC
1016
1420 rpm
C059
M2
1059
C102
M3
1102
C017
M1
Rated motor power
BASIC
1017
C060
M2
1060
C103
M3
1103
C018
M1
Rated motor current
BASIC
1018
C061
M2
1061
C104
M3
1104
C019
M1
Rated motor voltage
BASIC
1019
Depending on the drive voltage
class
C062
M2
1062
C105
M3
1105
C020
M1
Motor no-load power
ADVANCED
1020
0.0%
C063
M2
1063
C106
M3
1106
C021
M1
Motor no-load current
ADVANCED
1021
0%
C064
M2
1064
C107
M3
1107
C022
M1
Motor stator resistance
ENGINEERING
1022
C065
M2
1065
C108
M3
1108
C023
M1
Leakage inductance
ENGINEERING
1023
C066
M2
1066
C109
M3
1109