PROGRAMMING GUIDE
SINUS PENTA
335/486
NOTE
In Table 101:
0
⇒
Inactive input;
1
⇒
Active input;
X
⇒
Input having no effect.
C159 CW/CCW Input
C159
Range
0
÷
16
0
÷
24 if ES847 or ES870 is fitted
0
→
Inactive
1
÷
8
→
MDI1
÷
MDI8
9
÷
12
→
MPL1
÷
MPL4
13
÷
16
→
TFL1
÷
TFL4
17
÷
24
→
XMDI1
÷
XMDI8
Default
8
MDI8
Level
ADVANCED
Address
1159
Function
The
CW/CCW
function reverses the
active reference signal
: the connected motor
decelerates to zero following the preset deceleration ramp, then it accelerates
following the preset acceleration ramp until it reaches the new reference value.
C160 DCB Input
C160
Range
0
÷
16
0
÷
24 if ES847 or ES870 is fitted
0
→
Inactive
1
÷
8
→
MDI1
÷
MDI8
9
÷
12
→
MPL1
÷
MPL4
13
÷
16
→
TFL1
÷
TFL4
17
÷
24
→
XMDI1
÷
XMDI8
Default
0
Inactive
Level
ADVANCED
Address
1160
Control
IFD and VTC
Function
For FOC control, this function has no effect even if
C160
≠
0.
The DCB command enables
DC braking at stop
for a time period depending on the
speed value determining the input activation.
See the DC Braking Command Sent from Digital Input for more details.
C161, C162 UP and DOWN Inputs
C161 C162
Range
0
÷
16
0
÷
24 if ES847 or ES870 is fitted
0
→
Inactive
1
÷
8
→
MDI1
÷
MDI8
9
÷
12
→
MPL1
÷
MPL4
13
÷
16
→
TFL1
÷
TFL4
17
÷
24
→
XMDI1
÷
XMDI8
Default
0
Inactive
Level
ADVANCED
Address
1161, 1162
Function
This function increases (
UP
) or decreases (
DOWN
) the reference for which the
UpDown
source from MDI has been
selected
by adding a quantity
to the reference itself.
This also depends upon the following parameters:
C163
Up/Down Reset
P067
Up/Down Ramp Time
P068
Store Up/Down value at power off
P068a
Speed/Torque Up/Down Reset at stop
P068b
PID Up/Down Reset at stop
P068c
Speed/Torque Up/Down Reset at sources changeover
P068d
PID Up/Down Reset at sources changeover
P069
Up/Down Reference range