PROGRAMMING GUIDE
SINUS PENTA
471/486
Code
Meaning
Sinus Penta Fault
#
6000
Device software
6010
Software reset (Watchdog)
6100
Internal software
False Interrupt
A043
Generic Motorola
A063
1ms Interrupt OverTime
A071
Illegal Hardware
A141
6200
User software
User Fault
A040
6300
Data record
6301
Data record No. 1
SW Version KO
A092
6302
Data record No. 2
Optional Board not in
A054
6303
Data record No. 3
Illegal XMDI in DGI
A042
6304
Data record No. 4
Illegal XMDI in DGO
A052
6305
Data record No. 5
Illegal XMDI in MPL
A057
6306
Data record No. 6
FOC No Encoder
A079
6307
Data record No. 7
Illegal Encoder Cfg
A082
6308
Data record No. 8
Illegal Motor Selected
A098
6309
Data record No. 9
MDI6 Illegal Configuration
A100
630A
Data record No. 10
MDI8 Illegal Configuration
A101
7000
Supplementary modules
7100
Power
7110
Brake chopper
Braking Resistor Overload
A091
7120
Motor
Motor Not Connected
A097
7300
Sensor
PTC Alarm
A055
PTC Short Circuit
A056
REF < 4mA
A066
AIN1 < 4mA
A067
AIN2 < 4mA
A068
XAIN5 < 4mA
A069
REF > 20mA
A102
AIN1 > 20mA
A103
AIN2 > 20mA
A104
XAIN5 > 20mA
A086
7301
Tacho fault
Tracking Error
A080
Encoder Fault
A059
ABS Encoder Fault
A131
7310
Speed
Speed Alarm
A076
7500
Communication
Ser WatchDog
A061
SR1 WatchDog
A062
Fbs WatchDog
A070
Illegal Drive Profile Board
A095
Fieldbus Board Fault
A110
8000
Monitoring
8300
Torque control
8311
Excess torque
Motor OverHeated
A075
9000
External malfunction
External Alarm 1
A083
External Alarm 2
A084
External Alarm 3
A085