PROGRAMMING GUIDE
SINUS PENTA
53
/
486
M011 Torque Demand (%)
M011
Range
±
500
±
500 %
Note: The actual range depends on the torque limit values set for the
selected motor.
C047
–
C048
Motor 1
C090
–
C091
Motor 2
C133
–
C134
Motor 3
Active
Active for VTC and FOC controls only.
Address
1661
Function
With speed control: Torque demand of the speed regulator expressed as a percentage of the
motor rated torque.
With torque control: Torque reference processed with respect to the preset torque ramp time
and expressed as a reference of the motor rated torque.
M012 Torque Generated by the Motor (%)
M012
Range
±
500
±
500 %
Active
Active only for VTC and FOC controls.
Address
1662
Function
Approximate value of the torque produced by the motor and expressed as a percentage of the
rated torque of the selected motor.
M013 Torque Limit Demand before Ramps (Nm)
M013
Range
±
32000
±
32000 Nm
Note: The actual range depends on the preset torque limit values and the
rated torque of the selected motor.
C047
–
C048
Motor 1
C090
–
C091
Motor 2
C133
–
C134
Motor 3
Active
Active for VTC and FOC controls only.
Address
1663
Function
This is the limit value for the torque at constant speed. If an external torque limit is used, the
value of this measure is the torque limit obtained at constant speed; on the other hand, if the
torque limit is internal to the drive, this value is the actual torque limit expressed in Nm.
M014 Torque Limit Demand after Ramps (Nm)
M014
Range
±
32000
±
32000 Nm
Note: The actual range depends on the preset torque limit values and the
rated torque of the selected motor.
C047
–
C048
Motor 1
C090
–
C091
Motor 2
C133
–
C134
Motor 3
Active
Active for VTC and FOC controls only.
Address
1664
Function
This is the torque limit value being used, expressed in Nm.
M013a Speed Limit before the Ramps
M013a
Range
±
32000
±
32000 rpm
Active
Active for FOC only.
Address
1726
Function
Limit value at constant speed of the motor speed of rotation in “torque control with speed limit”
mode (C011=2 for Motor 1; C054, C097 for Motors 2 and 3).