PROGRAMMING GUIDE
SINUS PENTA
151/486
59: PID2 Reference
100.00%
Reference at constant speed of PID2
60: PID2 Set Point
100.00%
“Ramped” reference of PID2
61: PID2 Feedback
100.00%
PID2 Feedback
62: PID2 Error
100.00%
Error between reference and feedback of PID2
63: PID2 Out
100.00%
Output of PID2
64: Torque Demand
100.00%
Torque demand (value percent)
65: Actual Current Iv
5000A
Output Current Iv
66: RESERVED
RESERVED
67: RESERVED
RESERVED
68: RESERVED
RESERVED
69: RESERVED
RESERVED
Table 36 provides a brief description of each variable and its full-scale value used to set the minimum and maximum
value.
22.2.1.
O
PERAT ING
M
ODE OF
A
NALOG AND
F
REQUENCY
O
UT PUT S
This section covers the different representation modes to be selected for the analog and frequency outputs.
The following modes can be used for analog outputs:
0: Disabled
Disabled analog output (enables a RESERVED operating mode).
1: ± 10V
The analog output is set as a voltage output and the possible min. and max. output values range from
+/ – 10V. The selected variable has a positive or negative sign.
2: 0÷10V
The analog output is set as a voltage output and the possible min. and max. output values range from
0 to 10V. The selected variable has a positive or negative sign.
3: 0÷20mA
The analog output is set as a current output and the possible min. and max. output values range from
0 to 20mA. The selected variable has a positive or negative sign.
4: 4÷20mA
The analog output is set as a current output and the possible min. and max. output values range from
4 to 20mA. The selected variable has a positive or negative sign.
5: ABS 0÷10V
As 0÷10V output mode, but the selected variable is considered as an absolute value.
6: ABS 0÷20mA
As 0÷20mA output mode, but the selected variable is considered as an absolute value.
7: ABS 4÷20mA
As 4÷20mA output mode, but the selected variable is considered as an absolute value.
NOTE
Always check the min. and max. values of the outputs programmed in the relevant
parameters.
Three operating modes can be selected for the
Frequency Output
:
0: Disabled
The output frequency is disabled.
1: Pulse Out
MDO1 Digital Output is programmed as a frequency output. The selected variable has a positive or
negative sign.
2: ABS Pulse Out
As Pulse Out, but the selected variable is considered as an absolute value.
NOTE
When
P200
is not set to DISABLE, MDO1digital output is used as a frequency output
and any MDO1 settings in the DIGITAL OUTPUTS MENU are ignored.