SINUS PENTA
PROGRAMMING GUIDE
412
/
486
48. DATE
AND
TIME
MENU
48.1.
Overview
The Clock/Calendar of the control board (RTC – Real Time Clock) is based on the Clock/Calendar of the Data Logger
ES851 (please refer to the Motor Drives Accessories – User Manual).
NOTE
The Data and Time Menu may be accessed only if the Data Logger board is installed (even
the ES851 RTC version only) and if parameter
R021
Data Logger setting is set to 2: ENABLE.
The clock/calendar can be updated via special parameters. The display/keypad permits to immediately update the
clock/calendar: just select the Set Time page or the Set Date page and press
ENTER
. Press
ESC
to go to the next field;
press
ENTER
to confirm.
If you use the serial link of the inverter where the Data Logger is installed, the Clock/Calendar is viewed in the measure
parameters below. To update the Clock/Calendar via serial link, set the new values in
C310
to
C315
and send the edit
command (
C316
).
Parameters
R050
to
R053
set the rules for daylight saving time.
C
3 1 4
S e t
T I M E
D S T :
O F F
Press Save/Enter for
TIME setting
>
1 6 : 2 9 : 5 5
2 0 1 1 / J A N / 0 1 : S A T
First page of the Date and Time menu on the display/keypad
C 3 1 0
S e t
D A T E
1 6 : 2 9 : 5 5
Press Save/Enter for
DATE setting
> 2 0 1 1 / J A N / 0 1 : S A B
Second page of the Date and Time menu on the display/keypad
The date and time on the display/keypad are represented by the measures below:
Time (Hours)
Time (Hours)
Range
0
÷
23
0
÷
23 hours
Active
This measure is available only if the Data Logger ES851 is installed and
activated (
R021
= ENABLE).
Address
3342
Level
BASIC
Function
Time - hours (current value).