20. FOC
REGULATORS
MENU
20.1.
Overview
NOTE
Please refer to the MOTOR CONFIGURATION MENU as well.
NOTE
This menu may be accessed only if the FOC control is programmed for one of the
connected motors (
C010
=2 for motor n.1,
C053
=2 for motor n.2,
C096
=2 for motor n.3).
The FOC control has the same basic structure as that of any classic field oriented control.
The inner loops of FOC control are
two PI current regulators
having the same parameterization.
The first regulator controls
Iq torque current
; the second regulator controls
Id flux current
.
Iq
Torque current is computed based on the required torque set-point.
In
Slave mode
(torque reference), the required set–point comes from the external reference; in
Master mode,
the
torque set–point is given by the output of the
speed regulator
(see the SPEED LOOP AND CURRENT BALANCING
MENU) for the regulation of the motor speed of rotation.
Id
Flux current results from the output of the
flux regulator
, ensuring that the connected motor is always properly
fluxed.
This menu allows accessing the current PI regulators and flux regulators for the FOC control.
20.2.
List of Parameters P155 to P173
Table 34: List of parameters P155 to P173
Parameter
FUNCTION
User Level
Default
Values
MODBUS
Address
P155
Current regulator proportional constant, Mot n.1
ENGINEERING
3.00
755
P156
Current regulator integral time, Mot n.1
ENGINEERING
20.0 ms
756
P158
Flux regulator proportional constant, Mot n.1
ENGINEERING
0.00
758
P159
Flux regulator integral time, Mot n.1
ENGINEERING
33 ms
759
P162
Current regulator proportional constant, Mot n.2
ENGINEERING
3.00
762
P163
Current regulator integral time, Mot n.2
ENGINEERING
20.0 ms
763
P165
Flux regulator proportional constant, Mot n.2
ENGINEERING
0.00
765
P166
Flux regulator integral time, Mot n.2
ENGINEERING
33 ms
766
P169
Current regulator proportional constant, Mot n.3
ENGINEERING
3.00
769
P170
Current regulator integral time, Mot n.3
ENGINEERING
20.0 ms
770
P172
Flux regulator proportional constant, Mot n.3
ENGINEERING
0.00
772
P173
Flux regulator integral time, Mot n.3
ENGINEERING
33 ms