76
KH 8384-5 EN
Parameter lists
3 xd_error_ext_3
•
Reset comm. controller
• Attachment unit disturbed
•
Bin 2 deactivated
•
Reset appl. controller
• FF parameter
•
Mode unequal AUTO
• Temperature exceeding
14 Air Supply
15 Actuator Spring
16
Shifting Working Range
17 Friction
18 Leakage Pneumatic
19
Limit Working Range
20 Inner Leakage
21
External Leakage
22
Observing End Position
23
Connection Positioner Valve
24
Working Range
25
Temperature Error
26
PST/FST Status
27 Open Close Status
AO TRD: XD_FSTATE_OPT (32)
Storage class S; read/write capability r/w; supported modes O/M/A
Action on fault detection in AO TRD
• [Hold last value]
• Fail-safe position
•
Fault state value (XD_FSTATE_VAL)
AO TRD: XD_FSTATE_VAL (31)
Storage class S; read/write capability r/w; supported modes O/M/A
Fault state value to which the valve moves when the AO Transducer Block is in the O/S
mode and the action on fault detection has been selected in the XD_OOS_OPTS
parameter.
•
0 … 100 %, [0 %]