24
English (Original instructions)
from the generator name plate ratings.
■
The product is for outdoor use only.
■
Operation of the generator at altitudes above 1,000
m may require retuning. Consult a qualified service
technician.
■
When using extension lines or mobile distribution
networks the total length of lines for a cross section of
1.5 mm
²
should not exceed 60 m; for a cross section of
2.5 mm
²
this should not exceed 100 m.
■
The generating set must not be connected to other
power sources except another RIG2000PC with the
parallel kit RAC700 (sold separately).
■
Save these instructions. Refer to them frequently
and use them to instruct others who may use this
tool. If you loan someone this tool, loan them these
instructions also.
SERVICE
Servicing requires extreme care and knowledge and should
be performed only by a quali
fi
ed service technician. For
service, contact your nearest authorised service centre for
repair. When servicing, use only original manufacturer’s
replacement parts, accessories and attachments.
WARNING
Observe all normal safety precautions related to avoid
electrical shock.
DANGER
To avoid death or serious personal injury, do not
attempt to operate the product until you read thoroughly
and understand completely the operator’s manual. If
you do not understand the warnings and instructions
in the operator’s manual, do not use the product. Call
your nearest authorised service centre for assistance.
SAFETY LABELS
The information below can be found on the generator. For
your safety, please study and understand all of the labels
before starting the generator.
If any of the labels come off the product or become
hard to read, contact the authorised service centre for
replacement.
You will be killed or seriously hurt if you
do not follow the operator’s manual
instructions.
The generator is a potential source
of electric shock. Do not expose to
moisture, rain, or snow. Do not operate
with wet hands or feet.
Risk of Fire. Do not add fuel while the
product is operating.
Exhaust contains poisonous carbon
monoxide gas that can cause
unconsciousness or death. Operate
in well-ventilated, outdoor areas away
from open windows or doors.
Using a generator indoors can kill
you in minutes. Generator exhaust
contains carbon monoxide. This is a
poison you cannot see or smell.
Do not expose to rain or use in damp
locations.
Do not use E15 or E85 fuel (or fuel
containing greater than 10% ethanol)
in the product.
Never use inside a home or garage,
even if doors and windows are open.
Only use outside and far away from
windows, doors, and vents.
FUEL WARNING
No smoking when
fi
lling with unleaded fuel. Do not over
fi
ll.
Full level is 25 mm below the top of the fuel neck. Stop the
engine for
fi
ve minutes before refuelling to avoid the heat
from the muf
fl
er igniting fuel vapours.
ENGINE LUBRICANT WARNING
You must add oil before
fi
rst operating the generator.
Always check the oil level before each operation. The oil
level should always register within the hatched area on
the dipstick. The product is equipped with an oil sensor
which will automatically shut off the engine if oil level falls
below a safe limit.
Summary of Contents for RIG2000PC
Page 3: ...3 1 2 4 10 8 9 5 15 11 12 13 14 16 6 7 20 18 19 17 Fig 1 11 12 13 14 Fig 2 21 22 Fig 3...
Page 4: ...4 21 Fig 4 25 26 27 Fig 6 24 10 23 Fig 5 3 Fig 7...
Page 5: ...17 9 28 Fig 8 30 29 1 Fig 10 Fig 9 31 29 32 33 Fig 11...
Page 6: ...34 22 Fig 12 34 4 Fig 14 30 29 18 35 36 Fig 13 37 Fig 15...
Page 7: ......
Page 253: ...242 95 95 EC...
Page 254: ...243 CO 3...
Page 255: ...244...
Page 256: ...245 4 1 25 3 5 C 40 C 90 10 3 1000 1 5 2 60 2 5 2 100 RIG2000PC...
Page 257: ...246 E15 E85 10 25...
Page 262: ...251 SAE 10W 30 355 CO...
Page 263: ...252 2 1 3 SAE 10W 30 4 API SJ 2...
Page 264: ...253 5 E15 E85 10 10 E10 E15 E85 4 25 86 E85 5 7 CHOKE...
Page 265: ...254 5 RUN 6 6 15 30 RUN 5 6 1 30 8 12 DC 12...
Page 266: ...255 12 DC 30 120 9 30 1500...
Page 267: ...256 25 psi 10 11 1 4 12 100 6 13...
Page 268: ...257 0 60 0 70 0 024 0 028 1 2 1 8 1 4 14 15...
Page 269: ...258 1 20 3 50 6 100 300 1 1 CARB 1...
Page 270: ...259 DC DC DC...
Page 419: ...408 95 95 dB EC EurAsian...
Page 420: ...409 CO CO CO CO CO a 3...
Page 421: ...410 Replace any damaged parts...
Page 422: ...411 4 1 25 mm 1 3 m 5 40 90 10 3 Hz 1000 1 5 mm 60 m 2 5 mm 100 m RIG2000PC RAC700...
Page 423: ...412 E15 E85 10 25 mm 1 m 30...
Page 427: ...416 LED SAE 10W 30 355 ml P CO CO CO...
Page 428: ...417 CO CO LED 2 1 O 3...
Page 429: ...418 SAE 10W 30 4 API SJ 2 5 E15 E85 10 10 E10 E15 E85 4 25 86...
Page 430: ...419 85 5 7 a z 5 6 6 15 30 RUN 5 6 1 m 30 8 12...
Page 431: ...420 12 12 30 120 9 30...
Page 432: ...421 1500 25 psi 10 11 1 4 12 100 6...
Page 433: ...422 13 0 60 0 70 mm 0 024 0 028 1 2 1 8 1 4 14 15 o...
Page 434: ...423...
Page 435: ...424 20 3 50 6 100 300 1 1 CARB 1...
Page 436: ...425...
Page 437: ...426 86...
Page 439: ...428 95 95...
Page 440: ...429 CO CO CO CO 3...
Page 441: ...430...
Page 442: ...431 4 1 25 1 3 5 40 90 10 3 1000 1 5 2 60 2 5 2 100 RIG2000PC RAC700...
Page 443: ...432 E15 E85 10 25 1 30...
Page 447: ...436 SAE 10 30 355 CO CO...
Page 448: ...437 CO CO 2 1 3...
Page 449: ...438 SAE 10W 30 4 API SJ 2 5 E15 E85 10 10 E10 E15 E85 4 25 86 E85 5 7...
Page 450: ...439 5 6 6 15 30 5 6 1 30 8 12 12...
Page 451: ...440 12 30 120 9 30...
Page 452: ...441 1500 25 10 11 1 4 12 100 6...
Page 453: ...442 13 0 60 0 70 0 024 0 028 1 2 1 8 1 4 14 15...
Page 454: ...443 1 20 3 50 6 100 300 Clean air filter 1 1 CARB 1...
Page 455: ...444...
Page 456: ...445 86...
Page 475: ...WIRING DIAGRAM Fuse 10A...
Page 504: ...099979080005 01 Techtronic Industries GmbH Max Eyth Stra e 10 71364 Winnenden Germany...