![background image](http://html1.mh-extra.com/html/ryobi/44453401000001/44453401000001_original-instructions-manual_1504771005.webp)
3
English
|
EN
FR
DE
ES
IT
NL
PT
DA
SV
FI
NO
RU
PL
CS
HU
RO
LV
LT
ET
HR
SL
SK
EL
TR
UK
to adapt large hole grinding wheels.
N &KHFNWKDWWKHZRUNSLHFHLVSURSHUO\VXSSRUWHG
l) Use only grinding wheels approved by RYOBI.
m)
(QVXUH WKDW VSDUNV UHVXOWLQJ IURP XVH GR QRW
create a hazard, e.g., do not hit people, or ignite
flammable substances.
n) Always use protective safety glasses and ear
protectors.
o) Use other personal protective equipment, such as
gloves, apron, and helmet, when necessary.
p) Never place the product on the floor or other
surfaces while it is running. Grinding wheels
continue to rotate after the product is switched off.
Never touch the wheel or place it on the floor or
other surfaces while it is rotating.
q) Use the product only for approved applications.
Never use coolants or water or use the tool as a
IL[HGWRRO
r) Grip the product securely with both hands while
operating.
RESIDUAL RISKS
Even when the angle grinder is used as prescribed, it is
VWLOOLPSRVVLEOHWRFRPSOHWHO\HOLPLQDWHFHUWDLQUHVLGXDOULVN
factors. The following hazards may arise and the operator
should pay special attention to avoid the following:
Ŷ
,QMXU\FDXVHGE\WKURZQRIISDUWLFOHV
–
Metal or abrasive particles may enter the eyes and
cause severe permanent damage. Wear goggles
approved for grinding operations when operating
the product.
Ŷ
,QMXU\FDXVHGE\YLEUDWLRQ
–
/LPLWH[SRVXUH6HH5LVN5HGXFWLRQ
Ŷ
,QMXU\FDXVHGE\GXVW
–
:HDU DSSURSULDWH GXVW FRQWURO PDVN ZLWK ILOWHUV
suitable for protecting against particles from the
PDWHULDO EHLQJ ZRUNHG RQ DQG DEUDVLYH SDUWLFOHV
IURPWKHJULQGLQJGLVF'RQRWHDWGULQNRUVPRNH
LQWKHZRUNDUHD(QVXUHDGHTXDWHYHQWLODWLRQ
Ŷ
,QMXU\IURPFRQWDFWZLWKWKHJULQGLQJGLVF
–
7KH GLVF DQG ZRUNSLHFH ZLOO EHFRPH KRW GXULQJ
use. Wear gloves when changing discs or touching
ZRUNSLHFH .HHS KDQGV DZD\ IURP WKH JULQGLQJ
DUHD DW DOO WLPHV &ODPS WKH ZRUNSLHFH ZKHQHYHU
possible.
Ŷ
,QMXU\FDXVHGE\QRLVH
–
3URORQJHG H[SRVXUH WR QRLVH ZLOO LQFUHDVH WKH ULVN
of hearing damage, and the effects are cumulative.
:KHQXVLQJSRZHUWRROVIRUDQH[WHQGHGSHULRGRI
time, wear hearing protection.
RISK REDUCTION
It has been reported that vibrations from handheld tools
may contribute to a condition called Raynaud’s Syndrome
in certain individuals. Symptoms may include tingling,
QXPEQHVV DQG EODQFKLQJ RI WKH ¿QJHUV XVXDOO\ DSSDUHQW
XSRQ H[SRVXUH WR FROG +HUHGLWDU\ IDFWRUV H[SRVXUH WR
FROG DQG GDPSQHVV GLHW VPRNLQJ DQG ZRUN SUDFWLFHV
are all thought to contribute to the development of these
V\PSWRPV7KHUHDUHPHDVXUHVWKDWFDQEHWDNHQE\WKH
operator to possibly reduce the effects of vibration:
Ŷ
Keep your body warm in cold weather. When operating
WKHSURGXFWZHDUJORYHVWRNHHSWKHKDQGVDQGZULVWV
ZDUP,WLVUHSRUWHGWKDWFROGZHDWKHULVDPDMRUIDFWRU
contributing to Raynaud’s Syndrome.
Ŷ
$IWHU HDFK SHULRG RI RSHUDWLRQ H[HUFLVH WR LQFUHDVH
blood circulation.
Ŷ
7DNH IUHTXHQW ZRUN EUHDNV /LPLW WKH DPRXQW RI
H[SRVXUHSHUGD\
,I \RX H[SHULHQFH DQ\ RI WKH V\PSWRPV RI WKLV FRQGLWLRQ
immediately discontinue use and see your doctor about
these symptoms.
WARNING
,QMXULHVPD\EHFDXVHGRUDJJUDYDWHGE\SURORQJHGXVH
of a tool. When using any tool for prolonged periods,
HQVXUH\RXWDNHUHJXODUEUHDNV
KNOW YOUR PRODUCT
See page 127.
1. Switch button
2.
6SLQGOHORFNEXWWRQ
3.
*XDUGOHYHUORFN
4. Grinding wheel
5. Clamp nut
6. Wheel guard assembly
7. Disc flange
8.
$X[LOLDU\KDQGOH
9. Wrench
STARTUP PROTECTION
0DFKLQHV ZLWK D ORFNRQ VZLWFK DUH ¿WWHG ZLWK D FXWRXW
This prevents the machine from restarting by itself after a
SRZHUIDLOXUH:KHQUHVXPLQJZRUNVZLWFKWKHPDFKLQHRII
DQGWKHQVZLWFKLWEDFNRQDJDLQ
MAINTENANCE
WARNING
'R QRW PDNH DQ\ DGMXVWPHQWV ZKLOH WKH PRWRU LV LQ
motion.
The product should never be connected to a power
VXSSO\ ZKHQ DVVHPEOLQJ SDUWV PDNLQJ DGMXVWPHQWV
cleaning, performing maintenance, or when the product
is not in use. Disconnecting the product will prevent
DFFLGHQWDOVWDUWLQJWKDWFRXOGFDXVHVHULRXVLQMXU\
Ŷ
$IWHUXVHFKHFNWKHSURGXFWWRPDNHVXUHWKDWLWLVLQ
good condition.
Ŷ
,WLVUHFRPPHQGHGWKDW\RXWDNHWKHSURGXFWWRD5\REL
authorised service centre for a thorough cleaning and
lubrication at least once a year.
Ŷ
If the power supply cord is damaged, it must be replaced
only by the manufacturer or by an authorised service
FHQWUHWRDYRLGULVN&RQWDFWDXWKRULVHGVHUYLFHFHQWUH
WARNING
To ensure safety and reliability, all repairs should be
performed by an authorised service center or other
qualified service organisation.
Summary of Contents for 44453401000001
Page 58: ...56 _ l m n o p a b c d e a b c d e f a...
Page 60: ...58 _ 5D QDXG V 6 QGURPH Raynaud s Syndrome 1 2 3 4 5 6 7 8 9 5 REL V W n...
Page 61: ...59 _ EN FR DE ES IT NL PT DA SV FI NO RU PL CS HU RO LV LT ET HR SL SK EL TR UK PLQ 58...
Page 114: ...112 _ l m n o p a b c d e a b c d e f...
Page 116: ...114 _ 5D QDXG 5D QDXG 1 2 3 4 5 6 7 8 9 5 REL 5 REL...
Page 124: ...122 _ l m n o p a b c d e a b c d e f a...
Page 126: ...124 _ 1 2 3 4 5 6 7 8 9 5 REL V W...
Page 127: ...125 _ EN FR DE ES IT NL PT DA SV FI NO RU PL CS HU RO LV LT ET HR SL SK EL TR UK n PLQ...
Page 128: ...126 x 1 x 1 x 1 x 1...
Page 129: ...127 8 2 3 4 5 6 7 1 9...
Page 130: ...128 3 2 1 1 1 2 3 5 6...
Page 131: ...129 1 2 1 5 2 4 3 2 1 3 2 3 7 4...
Page 132: ...130...
Page 133: ...131 1 2 3 1 2 2 1 1 2...
Page 134: ...132 1 4 2 3 3 2 1 1 3 2 4...
Page 135: ...133 2 1 3 2 1 5 1 2 3 4 5 7 6 8...
Page 136: ...134 3 2 1 1 3 2 4...
Page 137: ...135 3 2 1 5 20151013v1...
Page 167: ......
Page 168: ...20151013v1 Techtronic Industries GmbH Max Eyth Stra e 10 71364 Winnenden Germany...