[17 - 26]
CHAPTER 17. TEST MODE
PRINTING TEST MODE
No.
1/2 Switch
680
O
Description
Setting
Range:
Units:
Default:
681
O
Description
Setting
Range:
Units:
Default:
682
O
Description
Setting
Range:
Units:
Default:
683
O
Description
Setting
Range:
Units:
Default:
684
O
Description
Setting
Range:
Units:
Default:
685
O
Description
Setting
Range:
Units:
Default:
686
Description
Setting
Range:
Units:
Default:
687
Description
Setting
Range:
Units:
Default:
688
Description
Data settings
Vertical Center Position Adjust
Sets the offset for the vertical print home position. (This data is stored in flash
memory on the ROSE board.)
-50 to +80 (-5.0 mm to +8.0 mm)
* (+ is upwards)
1 (0.1 mm)
0 mm
Drum Vertical Home Pos. Adj.
Sets the offset for the vertical print home position of the print drum. (This data
is stored in EEPROM of the drum.)
-50 to +80 (-5.0 mm to +8.0 mm)
* (+ is upwards)
1 (0.1 mm)
0 mm
Print Pressure HP Adjustment
(For Factory Use Only !)
Shifts the print drum pressure position on the 5 step print pressure on the
operation panel. (This data is stored in EEPROM on the print drum.)
-10 to +10 pulses
* (+)increases pressure, (-)decreases pressure
1 pulse
0 pulses
Paper Drum to Print Drum Distance Data Input
(For Factory Use Only !)
Sets the distance data from the paper drum to print drum. (This data is stored
in flash memory on the ROSE board.)
-10 to +10 pulses
* (+)increases pressure, (-)decreases pressure
1 pulse
0 pulses
Print Pressure Data Input
(For Field Seviceman Use)
Sets the print pressure data. (This data is stored in EEPROM on the print
drum.)
-10 to +10 pulses
* (+)increases pressure, (-)decreases pressure
1 pulse
0 pulses
Print Drum Diameter Correction
(For Old Master Making Unit Only)
Sets the tape thickness for print drum diameter correction. (This data is stored
in EEPROM on the print drum.)
0 to 100 (0 mm to 1.00 mm)
1 (0.01 mm)
0 mm
Drum Body ID Parameter Entry
When the drum vertical home Pos. Adj. are performed using test-mode
No.681, at the user where there are 2 or 3 V8000 machines, set ID Parameter
for machines in advance.
0 to 2
1
0
Warm-up Temperature
Warm-up function temperature setting
Setting
Range:
Units:
Default:
0 (Main Drive PCB with part number before 022-52502-403)
1 (Main Drive PCB with part number 022-52502-403 or after)
1 (Main Drive PCB with part number 022-52502-403 or after)
10 to 15 (10 to 15 degrees Celsius)
1 (1 degree Celsius)
13 (13 degrees Celsius)
Main Drive PCB: NEW - OLD selection
Switching the main motor drive constant by selecting correct Main Drive PCB
Summary of Contents for V8000 Series
Page 30: ... 1 19 CHAPTER 1 MAINTENANCE 4 Removing Exterior Covers Rear cover Rear cover P0112 ...
Page 31: ... 1 20 CHAPTER 1 MAINTENANCE Front doors L R Front door R Front door L P0113 P0114 P0115 P0116 ...
Page 42: ... 2 6 CHAPTER 2 MACHINE OVERVIEW MEMO ...
Page 54: ... 3 12 CHAPTER 3 MAIN DRIVE SECTION MEMO ...
Page 78: ... 4 24 CHAPTER 4 FIRST PAPER FEED SECTION MEMO ...
Page 92: ... 5 14 CHAPTER 5 SECOND PAPER FEED SECTION MEMO ...
Page 112: ... 6 20 CHAPTER 6 PAPER DRUM SECTION MEMO ...
Page 170: ... 8 44 CHAPTER 8 PRINT DRUM SECTION MEMO ...
Page 178: ... 9 8 CHAPTER 9 VERTICAL PRINT POSITION SECTION MEMO ...
Page 206: ... 11 20 CHAPTER 11 MASTER DISPOSAL SECTION MEMO ...
Page 209: ... 12 3 CHAPTER 12 FB ORIGINAL SCANNING SECTION MEMO ...
Page 263: ... 15 1 CHAPTER 15 TIMING CHARTS Contents This chapter is not completed ...
Page 333: ... 18 4 CHAPTER 18 FUNCTIONS MEMO ...
Page 355: ... 20 18 CHAPTER 20 PRINTED CIRCUIT BOARDS MEMO ...