[16 - 17]
CHAPTER 16. PANEL MESSAGES
DETAILED LIST OF PANEL MESSAGES
Error type
T44 [Pinch roller release motor lock]
Res et method
Press the [OK] key or the Reset button
→
Recovery operation (Pinch releas e), or switch on
power once again.
Error point
Error conditions
421
Pinch roller releas e s ens or does not s witch from ON
→
OFF within 1.3 s during the pinch
releas e action after the pinch roller releas e s ens or goes ON.
422
Pinch roller releas e s ens or does not s witch from OFF
→
ON within 1.3 s during the pinch
releas e action after the pinch roller releas e s ens or switches OFF.
423
Pinch roller releas e s ens or does not s witch from OFF
→
ON within 1.3 s during the pinch
pressurizing action after the pinch roller releas e s ens or goes ON.
424
Pinch roller releas e s ens or does not s witch from ON
→
OFF within 1.3 s during the pinch
pressurizing action after the pinch roller releas e s ens or s witches OFF.
Error type
T45 [2nd clam p opening and closing m otor lock]
Panel dis play
T45-***
!!System Error!!
Call Service
Res et method
To be res et by Technician only
Error point
Error conditions
542
0 angular sens or does not go ON within 3s when opening the end clam p.
544
180 angular sensor does not go ON within 3s when opening the top clam p.
546
Clamp plate loading position s ens or does not go ON within 1.5s when half-clos ing the top
clam p.
548
0 angular sens or does not go ON within 1.5s when closing the top clam p.
550
Clamp plate hom e position s ens or does not go ON within 1.5s when half-clos ing the end
clam p.
552
180 angular sensor does not go ON within 1.5s when closing the end clam p.
554
Overload current detection
555
Clamp plate hom e position s ens or is ON at the s tart of the open and close returning
operation and clamp plate hom e pos ition sensor dos e not go OFF within 3s during the
rotation of the motor toward 180 angular.
556
Clamp plate hom e pos ition s ensor dos e not switch from OFF to ON within 3s during the
rotation of the motor toward 0 angular when the open and clos e returning.
557
Clamp plate hom e position s ens or dos e not switch from ON to OFF within 3s during the
rotation of the motor toward 180 angular after the clam p plate home position sensor
switching from ON to OFF when the open and close returning.
Error type
T46 [Loading motor lock]
Res et method
Press the [OK] key or the Reset button , or s witch on power once again.
Error point
Error conditions
290
Overload current is detected when the loading motor rotates m aster feeding direction.
291
Overload current is detected when the loading motor rotates master reverse direction.
Panel dis play
T44-***
!!System Error!!
Press Reset Key.
If Recovery has Failed, Call Service
T46-***
!!System Error!!
Press Reset Key.
If Recovery has Failed, Call Service
Panel dis play
Summary of Contents for V8000 Series
Page 30: ... 1 19 CHAPTER 1 MAINTENANCE 4 Removing Exterior Covers Rear cover Rear cover P0112 ...
Page 31: ... 1 20 CHAPTER 1 MAINTENANCE Front doors L R Front door R Front door L P0113 P0114 P0115 P0116 ...
Page 42: ... 2 6 CHAPTER 2 MACHINE OVERVIEW MEMO ...
Page 54: ... 3 12 CHAPTER 3 MAIN DRIVE SECTION MEMO ...
Page 78: ... 4 24 CHAPTER 4 FIRST PAPER FEED SECTION MEMO ...
Page 92: ... 5 14 CHAPTER 5 SECOND PAPER FEED SECTION MEMO ...
Page 112: ... 6 20 CHAPTER 6 PAPER DRUM SECTION MEMO ...
Page 170: ... 8 44 CHAPTER 8 PRINT DRUM SECTION MEMO ...
Page 178: ... 9 8 CHAPTER 9 VERTICAL PRINT POSITION SECTION MEMO ...
Page 206: ... 11 20 CHAPTER 11 MASTER DISPOSAL SECTION MEMO ...
Page 209: ... 12 3 CHAPTER 12 FB ORIGINAL SCANNING SECTION MEMO ...
Page 263: ... 15 1 CHAPTER 15 TIMING CHARTS Contents This chapter is not completed ...
Page 333: ... 18 4 CHAPTER 18 FUNCTIONS MEMO ...
Page 355: ... 20 18 CHAPTER 20 PRINTED CIRCUIT BOARDS MEMO ...