[16 - 15]
CHAPTER 16. PANEL MESSAGES
DETAILED LIST OF PANEL MESSAGES
Error type
T37 [MCTL PCB no battery]
Reset method
Replace battery.
Error point
Error conditions
010
No MCTL PCB backup battery. (The voltage of battery is under 2.3V)
Error type
T38 [1s t clamp opening and clos ing motor lock]
Panel display
T38-***
!!System Error!!
Call Service
Reset method
To be reset by Technician only
Error point
Error conditions
542
0 angular s ens or does not go ON within 3s when opening the end clam p.
544
180 angular sensor does not go ON within 3s when opening the top clam p.
546
Clam p plate loading position s ensor does not go ON within 1.5s when half-clos ing the top
clamp.
548
0 angular s ens or does not go ON within 1.5s when clos ing the top clam p.
550
Clam p plate hom e pos ition sensor does not go ON within 1.5s when half-clos ing the end clam p.
552
180 angular sensor does not go ON within 1.5s when clos ing the end clam p.
554
Overload current detection
555
Clamp plate home pos ition sensor is ON at the start of the open and clos e returning operation
and clam p plate hom e pos ition sensor dose not go OFF within 3s during the rotation of the m otor
toward 180 angular.
556
Clam p plate hom e position s ens or dose not s witch from OFF to ON within 3s during the rotation
of the motor toward 0 angular when the open and close returning.
557
Clam p plate hom e pos ition sensor dose not switch from ON to OFF within 3s during the rotation
of the motor toward 180 angular after the clam p plate hom e position s ens or s witching from ON
to OFF when the open and clos e returning.
Error type
T39 [1s t disposal plate motor lock]
Reset method
Press the [OK] key or the Res et button
→
Recovery operation (HP resetting).
Error point
Error conditions
311
Dis posal plate hom e sensor does not go ON within 3 s when the disposal plate returns.
313
Dis posal plate hom e sensor does not switch from ON to OFF within 0.5 s after the disposal plate
blaking goes ON.
314
Dis posal plate limit sensor does not go ON within 3 s when the dis pos al plate performs
compres sion.
315
Overload current was detected when the disposal plate motor operates. (It is not monitored
between 300ms ec after motor ON)
316
Both the dis pos al plate limit sensor and dispos al plate home s ens or were ON at the start of the
operation.
Panel display
T39-***
!!System Error!!
Press Res et Key.
If Recovery has Failed, Call Service
Panel display
T37-***
!!System Error!!
Press Res et Key.
If Recovery has Failed, Call Service
Summary of Contents for V8000 Series
Page 30: ... 1 19 CHAPTER 1 MAINTENANCE 4 Removing Exterior Covers Rear cover Rear cover P0112 ...
Page 31: ... 1 20 CHAPTER 1 MAINTENANCE Front doors L R Front door R Front door L P0113 P0114 P0115 P0116 ...
Page 42: ... 2 6 CHAPTER 2 MACHINE OVERVIEW MEMO ...
Page 54: ... 3 12 CHAPTER 3 MAIN DRIVE SECTION MEMO ...
Page 78: ... 4 24 CHAPTER 4 FIRST PAPER FEED SECTION MEMO ...
Page 92: ... 5 14 CHAPTER 5 SECOND PAPER FEED SECTION MEMO ...
Page 112: ... 6 20 CHAPTER 6 PAPER DRUM SECTION MEMO ...
Page 170: ... 8 44 CHAPTER 8 PRINT DRUM SECTION MEMO ...
Page 178: ... 9 8 CHAPTER 9 VERTICAL PRINT POSITION SECTION MEMO ...
Page 206: ... 11 20 CHAPTER 11 MASTER DISPOSAL SECTION MEMO ...
Page 209: ... 12 3 CHAPTER 12 FB ORIGINAL SCANNING SECTION MEMO ...
Page 263: ... 15 1 CHAPTER 15 TIMING CHARTS Contents This chapter is not completed ...
Page 333: ... 18 4 CHAPTER 18 FUNCTIONS MEMO ...
Page 355: ... 20 18 CHAPTER 20 PRINTED CIRCUIT BOARDS MEMO ...