MediorNet sync master selection
The decision which Frame becomes master follows a few decisions. The first Frame, which can answer
the following questions beginning by 1.) with yes, become sync master.
1.)
Is a sync signal detected on the Sync Input?
2.)
Is the sync priority set to any other level than
none?
3.)
Is the sync signal error free?
4.)
Is the sync priority higher than that of other Frames?
If some Frames have the same answers to all questions, the decision is done by a unique Frame ID.
Rank
Sync. Priority
Sync. Error
Sync. In
1
Master
none
detected
2
Secondary Master
none
detected
3
Tertiary Master
none
detected
4
Master
Sync Lost
detected
5
Secondary Master
Sync Lost
detected
6
Tertiary Master
Sync Lost
detected
7
none
none
detected
8
Master
none
none
9
Secondary Master
none
none
10
Tertiary Master
none
none
11
Master
Sync Lost
none
12
Secondary Master
Sync Lost
none
13
Tertiary Master
Sync Lost
none
14
none
none
none
USO