135
MediorNet User Manual 2.00.0
MN-RN300 RockNet CONFIGURATION
The contents of the tabs
RockNet 1 and RockNet 2 have the same structure.
Figure 178: MN-RN300 RockNet CONFIGURATION
The meanings of the different fields are described in the table below:
Sample Rate
Selection of the sample rate (48kHz/96kHz)
(Left) Input MADI / Mono
Channel Name
Name of the RockNet-Input Channel / -SubChannels
(Right) Output MADI /
Mono Channel Name
Name of the RockNet-Output Channel / -SubChannels
On the right of the RockNet Output-Channels / -SubChannels are the symbols for the 1kHz test signal and
the muting. A left-click on these icons will enable/disable the function.
The amount of available RockNet-SubChannels depends on the selected sample rate:
64 SubChannels in 48kHz sample rate mode
32 SubChannels in 96kHz sample rate mode