71
MediorNet User Manual 2.00.0
3.4
MN-Compact Status LEDs
The meaning of the Status LEDs of the MediorNet-Compact is listed in following table:
MN-Compact-System
LED
POWER A/B
EXTERNAL DC
green
OK
OK
off
no power
no power
LED
DC FAULT (rear side)
red
error
off
no voltage / Voltage OK
LED
SYNC MASTER
FAN L/R
red
--
error
green
Frame is SYNC Master
OK
orange
Frame is SYNC Master and in "locking state"
(attempt to synchronize to a Sync signal)
Fan cannot reach maximum
rotation
off
Frame is SYNC Slave
--
If the fan status LED is orange, ensure the dust filter is clean and the air flow through the
ventilation opening on the left and right side of the Frame is not blocked.
MN-Compact-LINK
LED
Link Status (left)
Link Activity (right)
red
physical link up, MediorNet link up
SFP RX power too high/low
Connections present and interrupted
green
physical link up, MediorNet link up
Connections present and ok
orange
physical link up, MediorNet link down
--
off
physical link down, MediorNet link down
no Connections present
Both LEDs are green for about 5 seconds while plugging an SFP
Both LEDs are red if an incompatible SFP is plugged
USO
RESTRITO
Summary of Contents for MediorNet
Page 1: ...MediorNet User Manual USO RESTRITO ...
Page 11: ...11 MediorNet User Manual 2 00 0 Figure 2 overview of topology USO RESTRITO ...
Page 92: ...92 MediorNet User Manual 2 00 0 Figure 136 Output Channel configuration USO RESTRITO ...
Page 308: ...308 MediorNet User Manual 2 00 0 Notes USO RESTRITO ...
Page 309: ...309 MediorNet User Manual 2 00 0 Notes USO RESTRITO ...