53
MediorNet User Manual 2.00.0
Figure 82: MediorNet-Com pact-PRO (rear view)
Power Supply
All Compact devices have an internal power supply and contain two IEC connectors for the mains
connection. One IEC connector is located in the front side (
Power-A), the other one on the rear side (Power-B).
A switch on the rear side selects the desired input. Additionally there is an XLR-4 plug on the rear side of the
device to power the system via an external power supply (12Vdc / 7A). PSU redundancy is available by using
one IEC mains plus an external power supply.
Figure 83: MN-Com pact PSU
1
SELECT
selection of IEC connector
POWER A
(front side) or
POWER B
(rear
side)
2
POWER A
(front side)
IEC
connect via locking IEC connector of provided power supply cord
3
POWER B
(rear side)
IEC
connect via locking IEC connector of provided power supply cord
4
EXT PSU
XLR-4
external power supply 12 VDC ±10%,
max. ripple 250mV / 20 MHz, 8A constant / 14A peak (250ms)