5682 message log where the
following are set:
1: mm:ss:ms
0: mm:ss (time)
5844
USB
1 Transfer Rate
Sets the speed for USB data transmission.
[Full Speed], [Auto Change]
2 Vendor ID
Sets the vendor ID:
Initial Setting: 0x05A Ricoh Company
[0x0000 to 0xFFFF/1] DFU
3 Product ID
Sets the product ID.
[0x0000 to 0xFFFF/1] DFU
4 Device Release No.
Sets the device release number of the BCD (binary coded decimal) display.
[0000 to 9999/1] DFU
Enter as a decimal number. NCS converts the number to hexadecimal number recognized as
the BCD.
5845
Delivery Server Setting
Provides items for delivery server settings.
3 Retry Interval
Determines the time interval between retries before the machine returns to standby after an
error occurs during an image transfer with the delivery scanner or SMTP server.
[60 to 900/300/1]
4 Number of Retries
Determines the number of retries before the machine returns to standby after an error occurs
during an image transfer with the delivery or SMTP server.
[0 to 99/3/1]
5. Service Tables
320
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...