This SP displays the external RC Gate installation status.
0: Basil not registered
1: Basil registered
2: Device registered
23
Connect Mode (N/M)
This SP displays and selects the Embedded RC Gate connection method.
0: Internet connection
1: Dial-up connection
61
NotiTime ExpTime DFU
Notification of Expiration Time
Proximity of the expiration of the certification.
62
HTTP Proxy Use
This SP setting determines if the proxy server is used when the machine communicates with
the service center.
63
HTTP Proxy Host
This SP sets the address of the proxy server used for communication between embedded
RCG-N and the gateway. Use this SP to set up or display the customer proxy server address.
The address is necessary to set up embedded RCG-N.
Note: The address display is limited to 128 characters. Characters beyond the 128th
character are ignored. This address is customer information and is not printed in the SMC
report.
64
HTTP Proxy Port
This SP sets the port number of the proxy server used for communication between embedded
RCG-N and the gateway. This setting is necessary to set up embedded RCG-N.
Note: This port number is customer information and is not printed in the SMC report.
65
HTTP Proxy Aut Usr
This SP sets the HTTP proxy certification user name.
Note:
• The length of the name is limited to 31 characters. Any character beyond the 31st
character is ignored.
• This name is customer information and is not printed in the SMC report.
66 HTTP Proxy Aut Pass
SP5-xxx Mode
307
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...