11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain:LTemp
[0 to 50/0/5]
1935
PreFB Steps
Pressure Feedback Control Steps
This SP changes the stepped adjustments of SP1932 (Target Temp: Pressure Roller) by using
the sum of the settings of SP1932 (Target Temp: Pressure Roller) +SP1935 (Press FB Control
Steps) as the steps.
Example
• If the pressure roller temperature for SP1935-1 is 100
o
C, the target hot roller
temperature is 195
o
C ("100" is SP1932, "195" is SP1931).
• If the pressure roller temperature 120
o
C (= "100"+"20", this is SP1935), the
target hot roller temperature is 175
o
C (="195"-"20", this is SP1931 – SP1934)
• If the setting is "0", the temperature settings of SP1931 do not change.
1 Plain: Mode1
[0 to 50/20/5]
2 Plain: Mode2
[0 to 50/25/5]
3 Plain: Mode3
[0 to 50/30/5]
4 Plain: Mode4
[0 to 50/20/5]
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
SP1-xxx Feed