0000: OFF, 0001: ON
210
LogType: Job1 DFU
Setting: Log Type: Job 1
[0 to 0xFFFFFFFF/0/1]
211
LogType: Job2 DFU
Setting: Log Type: Job 2
[0 to 0xFFFFFFFF/0/1]
212
LogType: Access DFU
Setting: Log Type: Access
[0 to 0xFFFFFFFF/0/1]
213 Primary Srv DFU
Setting: Primary Srv
214 Secondary Srv DFU
Setting: Secondary Srv
215
Start Time DFU
Setting: Start Time
[0 to 0xFFFFFFFF/0/1]
216
Internal Time DFU
Setting: Interval Time
[1 to 100/1/1]
217
Timing DFU
Setting: Timing
[0 to 2/0/1]
0: Transmission off
1: Transmission 1 by 1
2: Periodic transmission
5849
Installation Date
Displays or prints the installation date of the machine.
1 Display
Displays the installation date. The installation date is set automatically
after test copies are done at the installation site.
2 Print
Determines whether the installation date or total count is printed on
the total counter printout.
[0 to 1/1]
0: No Print
1: Print
SP5-xxx Mode
325
5
Summary of Contents for Neptune-P1