Sets the alarm to sound for the specified jam level (document misfeeds are not included).
[0 to 3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
Error Alarm
Sets the error alarm level. Japan only DFU
[000 to 255 / 001 / 100 copies per step]
5507
Supply Alarm DFU
1 Paper Size
Switches the control call on/off for the paper supply. DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified number transfer sheets for each paper size
(A3, A4, B4, B5, DLT, LG, LT, HLT)
3 Toner
Switches the control call on/off for the toner end. DFU
0: Off, 1: On
If you select “1” the alarm will sound when the main machine detects toner end.
The “Interval nn" SP's below specify the paper control call interval for the referenced
paper sizes. DFU
[00250 to 10000 / 1000 / 1 Step]
97 Interval: 841mm
164 Interval: LG
98 Interval: 594mm
165 Interval: Foolscap
99 Interval: 420mm
166 Interval: LT
100 Interval: 297mm
175 Interval: 12x18
101 Interval: 210mm
225 Interval: 36inch
SP5-xxx Mode
297
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...