4 Level 4
[1000 to 15000/9100/1 mm]
5 Level 5
[1000 to 15000/12100/1 mm]
1946 PreFBStp:TTD
Pressure Roller Feedback Stop: Target Temperature
Differential
This SP calculates the hot roller target temperature while pressure roller feedback control is
stopped. This SP determines the target hot roller temperature while pressure roller feedback
control is not operating. The temperature is determined based on the paper type and length of
the paper (Length Level).
Note: The Length Levels (1 to 5) are defined by SP1945.
1 LLvl1:Norm
Length Level 1: Normal
[0 to 30/15/1
o
C]
2 LLvl2:Norm
Length Level 2: Normal
[0 to 30/10/1
o
C]
3 LLvl3:Norm
Length Level 3: Normal
[0 to 30/7/1
o
C]
4 LLvl4:Norm
Length Level 4: Normal
[0 to 30/5/1
o
C]
5 LLvl5:Norm
Length Level 5: Normal
[0 to 30/3/1
o
C]
11 LLvl1:Cold
Length Level 1: Cold Start
[0 to 30/10/1
o
C]
12 LLvl2:Cold
Length Level 2: Cold Start
[0 to 30/5/1
o
C]
13 LLvl3:Cold
Length Level 3: Cold Start
[0 to 30/3/1
o
C]
14 LLvl4:Cold
Length Level 4: Cold Start
[0 to 30/0/1
o
C]
15 LLvl5:Cold
Length Level 5: Cold Start
16 LLvl0:Cold
Length Level 0: Cold Start
1947 PreFB Stp:TP
Press FB Stop: Time Period
This SP sets the length of time that pressure roller feedback is suspended for the paper lengths
defined by SP1945.
• Pressure roller feedback control begins when the time set with this SP has elapsed after
paper feed starts.
• As more paper is fed for a multiple print job, the time setting for succeeding sheets is
overwritten.
SP1-xxx Feed
273
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...