050 1284 Compatible
Enables and disables bi-directional communication on the parallel connection between the
machine and a computer.
[0 to 1/1]
0:Off
1: On
052 ECP
Disables and enables the ECP feature (1284 Mode) for data transfer.
[0 to 1/1]
0: Disabled
1: Enabled
65 Job Spool Setting
Switches job spooling spooling on and off.
0: No spooling 1: Spooling enabled
66 Job Spool Clear
This SP determines whether the job interrupted at power off is resumed at the next power
on. This SP operates only when SP5828065 is set to 1.
1: Resumes printing spooled jog.
0: Clears spooled job.
69 Job Spool Protocol
This SP 8etermines whether job spooling is enabled or disabled for each pro to col. This is
a 8-bit setting.
0
LPR
4
BMLinks (Japan Only)
1
FTP (Not Used)
5
DIPRINT
2
IPP
6
Reserved (Not Used)
3
SMB
7
Reserved (Not Used)
90 TELNET (0:OFF 1:ON)
Disables or enables Telnet operation. If this SP is disabled, the Telnet port is closed.
[0 to 1/1]
5. Service Tables