• Do not add the second pack at this time.
• Open the first pack of developer [1].
• Slowly add the developer from the first pack into the development unit, as you move the pack
from left to right until the pack is empty.
• An equal amount of developer must be spread along the entire open slot of the development
unit.
6. Close the toner hopper cover [2].
7. Close the upper unit [3].
8. Connect the power supply cord. Switch the main power switch on. The main motor switches on and
distributes the developer evenly inside the development unit.
9. Wait about 10 sec.
10. Turn the main power switch off.
11. Disconnect the power cord.
12. Open the upper unit.
13. Open the toner hopper cover.
14. Open the second 1 kg pack of developer, then slowly add it to the development unit. Move the pack
from left to right until it is empty.
15. Use a clean cloth to clean the edges around the slot of the development unit.
16. Close the upper unit.
Main Machine Installation (G180)
31
1
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...