For every change of "1", speed is adjusted 1/1848 or approximately 0.054%.
Std: (19.6608 MHz/8)/1848 = 1329.97 pps
Example: If the setting changed by "+10" then:
(19.6608 MHz/8)/(1848-10) =
(19.6608 MHz/8)/(1838) = 1337.11 pps
1911
BP Strt Adj
By-pass Feed Start Timing Adj.
Adjusts the time that the operator has to adjust the paper skew manually when feeding paper
manually from the bypass tray..
[1.0 to 8.0/2.0/0.1 sec.]
1912
Fed M SpdAdj
Feed Motor Speed Adjustment
Adjusts the feed motor speed for the type of print medium in use (plain paper, translucent
paper, film).
Std: (70 MHz/32)/1635 = 1338 pps
For every change of "1", speed is adjusted 1/1635 or approximately 0.06%.
Example: If the setting is changed by "+10" then:
(70 MHz/32)/(1635-10) =
(70 MHz/32)/(1625) = 1346 pps
1 Plain
[-100 to +100/-10/1%]
2 Translucent
[-100 to +100/0/1%]
3 Film
[-100 to +100/-10/%1]
1916
Fus M SpdAdj
Fusing Motor Speed Adj.
SP1916 1 to 013 adjust the basic fusing motor speed and correct the speed for different
widths of paper to prevent skew in the paper feed path. Note:
The actual adjustment that the machine applies is the sum of the width adjustment (1916 010
to 013) and the paper type adjustment (1916 021 to 045).
10 Width:611mm more
[-100 to +100/0/1]
11 Width:461-610mm
[-100 to +100/5/1]
12 Width:298-460mm
[-100 to +100/9/1]
5. Service Tables
250
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...