1 FeedM:R1 DFU
Feed Motor: 1st Roll
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1635 or approximately 0.06%
Std: (70 MHz/32)/1635 = 1338 pps
Example: If the setting is changed by "+10" then:
(70 MHz/32)/(1635-10) =
(70 MHz/32)/(1625) = 1346 pps
2 FeedM:R2 DFU
Feed Motor: 2nd Roll
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1635 or approximately 0.06%
Std: (70 MHz/32)/1635 = 1338 pps
Example: If the setting is changed by "+10" then:
(70 MHz/32)/(1635-10) =
(70 MHz/32)/(1625) = 1346 pps
5 FeedM:CutS DFU
Feed Motor : Cut Paper Tray
[-30 to +30/0/1]
For every change of "1", speed is adjusted 1/1063 or approximately 0.094%
Std: (19.6608 MHz/32)/1063 = 578 pps
Example: If the setting is changed by "+10" then:
(19.6608 MHz/32)/(1063-10) =
(19.6608 MHz/32)/(1053) = 583 pps
6 Main Motor DFU
[-80 to +80/0/1]
For every change of "1", speed is adjusted 1/2485 or approximately 0.035%.
Std: (19.6608 MHz/8)/2485 = 988.07 pps
Example: If the setting changed by "+10" then:
(19.6608 MHz/8)/(2485-10) =
(19.6608 MHz/8)/(2475) = 992.9 pps
7 Fusing Motor DFU
[-100 to +100/7/1
SP1-xxx Feed
249
5
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...