PAGE 122
OPERATOR’S MANUAL ULTRA GUIDANCE PSR ISO
CHAPTER
TROUBLESHOOTING
Error-No.:
Description
Cause
Troubleshooting
1701
Start signal ultra sonic no
voltage.
- Outlet at the PSR iBox is defective.
- Check cables from PSR iBox to front
plug box.
- Short circuit in cable.
1702
GPS no voltage.
- Outlet at the PSR iBox is defective.
- Check cables from PSR iBox to GPS-
receiver.
- Short circuit in cable.
1703
Sensors no voltage.
- Outlet at the PSR iBox is defective.
- Check the cables from PSR iBox to all
sensors.
- Short circuit in cable.
1710
No voltage relay input-side.
- Fuse defective.
- Check fuses in PSR iBox and supply
lines.
- Supply voltage for outlets not yet
switched on.
- Check whether supply voltages are
switched on.
1711
No voltage relay output-
side.
- Relay in iBox Lt is defective.
- Contact your Reichhardt support.
2100
Incremental axle.
- no pulse signal at channel A.
- Check cables from PSR iBox to
incremental sensor (for example: RDU).
2101
Incremental axle.
- no pulse signal at channel B.
- Check cables from PSR iBox to
incremental sensor (for example: RDU).
2102
Incremental axle.
- no pulse signal at channel A and B. - Check cables from PSR iBox to
incremental sensor (for example: RDU).
2150
John Deere Autotrac.
- No communication.
- Check cables from PSR iBox to JD
Autotrac Motor.
2200
Footswitch defective.
- Footswitch engaged too long.
- Check footswitch.
- Short circuit in cable.
- Check the cables of the PSR iBox to
footswitch.
- Footswitch defective.
2300
ISO Cat hydraulic main
switch off.
- The hydraulics are disengaged by
switch.
- Check hydraulic switch.
2301
ISO Cat communication
error.
- Poor CAN connection.
- Check cables from PSR iBox to CAT CAN-
Bus.
- Activate ISO implementation level
3 on the CAT screen.
- Activate ISO level 3 on the CAT screen.
2310
ISO Fendt communication
error Can Bus 1.
- no information from Can Bus
received.
- Contact your Reichhardt support.
2311
ISO Fendt communication
error Can Bus 2.
- No information from Can Bus
received.
- Contact your Reichhardt support.
2315
ISO AGCO combine har-
vester communication error
Can Bus 1.
- no information from Can Bus
received.
- Contact your Reichhardt support.
2316
ISO AGCO combine har-
vester communication error
Can Bus 2.
- No information from Can Bus
received.
- Contact your Reichhardt support.
2317
ISO AgriFac communication
error.
- No information from Can Bus
received.
- Contact your Reichhardt support.