OPERATOR’S MANUAL ULTRA GUIDANCE PSR ISO
PAGE 103
CHAPTER
PSR TAC
7.4.
Main menu PSR TAC
Display:
Main screen
Tap the function key
to change to the main menu PSR TAC.
7.4.1. TAC sensor calibration
Choose
and confirm the selection.
To get consistently good results with the TAC sensor, it is advised
re-calibrate it occasionally. Especially during initial use or after
lengthy periods of no use.
Make sure the plastic wand is in rest position. It should not touch
anything or be moved by any action. Do not touch the sensor. The
value should be between 40 and 70.
Press and hold the function key
until the stored symbol
appears. Proceed as described in chapter 4.12.
Advice!
For more consistent results, the vehicle may
have two sets of sensors. When pressing the function
keys
,
the operator will first see S1 then S2
then S3 and S4. All sensors will be calibrated together.
Picture 179:
Main screen PSR TAC
Picture 180:
Select TAC sensor
Picture 181:
Calibrate TAC sensor