- 48 -
15.7. Additional Parameters for a Weighing Process
Modification of weighing functions enables programming balance operation.
Procedure:
•
Press grey workspace area.
•
The following submenus are displayed: Settings, Buttons, Information, Printouts,
Profile.
•
Select submenu, press it, select submenu item that is to be modified.
<Settings> - additional options related to weighing mode,
<Keys> - defining quick access buttons,
<Information> - supplementary data on weighing process displayed in an Info field,
<Printouts> - selecting printout type,
<Profile> - selecting profile that is to be active during balance operation,
<SETTINGS> - weighing process related data such as:
−
Tare mode
Available options:
•
SINGLE:
mass value saved to balance memory on single pressing of TARE key. Subsequent
pressing of TARE key determines new tare value. Selecting product or packaging to
which tare value is assigned causes automatic deleting of previously assigned tare
value.
•
CURRENT SUM
total value of currently entered product and packaging tare values (result of
selection of product and packaging from the database) with possibility to add tare
value entered manually. When new tare value for a product or packaging is set
again then tare value entered manually gets deactivated.TOTAL SUM
total value of all entered tare values.
•
AUTOTARE:
Means of operation:
Each first stable measurement result is tared. NET sign is displayed. Now you can
determine net mass of weighed load. Upon unloading the weighing pan and
autozeroing, tare value is automatically deleted
−
Automatic footer printout
Available options:
MODE – None – manual footer printout,
Sum of measurements – footer is printed when mass value entered in
<Threshold> parameter gets exceeded.
Measurements quantity – footer is printed when a pre-defined
measurements quantity (a batch) set in parameter <Threshold> is carried
out.
THRESHOLD – setting the threshold value determining footer printout.
For <Sum of measurements> parameter, threshold value is determined in
measuring unit [g], for <Measurements quantity> parameter the unit is not
determined, the provided value specifies carried out measurements
quantity.
−
Printout/Enter mode
•
PRINT/RELEASE BUTTON (manual operation)
Never – printout disabled.
First stable – first stable measurement is recorded.
Each stable – all stable measurements are registered.