![Quasonix HyperTrack Software Instruction Manual Download Page 93](http://html1.mh-extra.com/html/quasonix/hypertrack/hypertrack_software-instruction-manual_3539179093.webp)
HyperTrack™
Software Instruction
84
Quasonix, Inc.
Figure 98: Main Screen, RSSI
—
Signal Meter Channels
4.2.3.3.5.1 RSSI Receivers Auto Rx
The Auto Rx feature is activated by the button above each receiver signal level display (4). The button enables the
Auto Rx for the channel below the button. The button illuminates green when enabled. In Figure, the buttons above
channels 1, 2, and 3 are selected and illuminate green. Those channels automatically switch to the receiver channel
with the highest displayed signal level. The auto receiver Auto Rx Off button must be enabled and illuminate yellow
for auto channel switching to take place. An example is shown in Figure 99.
Figure 99: Main Screen, RSSI
—
Activated Auto Rx Channels
4.2.3.3.5.2 RSSI Receivers Signal Level
The Auto Rx feature displays the active/selected AGC level for each tracking channel. The level is represented by
the illuminated green bar in the display scale. In Figure 100, the selected tracking channel is channel four V COMB,
indicated by a green border around the channel meter. The signal strength of the radiated target is also displayed
numerically underneath each meter provided that the AGC BNC cables for each channel from the back of the
Receiver AGC outputs are connected to the correct HTAC AGC inputs.