The data recording frequency is set via the Rate drop down menu, located in the General window, circled in Figure
18. The rate is adjustable between 1 Hz and 100 Hz. In the example on the left figure, all parameters highlighted
green are recorded at the selected rate of 100 Hz. All gray parameters are not logged.
Figure 18: Log Settings
—
Two Examples with Different Settings Selected
The selected logging parameters in Figure 19 are continuously collected for all sixteen (16) channels, but recorded
for only the selected (green) active tracking channels. If Auto Receive (Auto Rx) is selected and the Active Channel
parameter is green, only the channel which is actively tracking the target (LHCP or RHCP, for example) will be
recorded. If the tracking channel auto switches to a new channel, the logged data switches to the new tracking
channel and is recorded for that channel.