![Quasonix HyperTrack Software Instruction Manual Download Page 31](http://html1.mh-extra.com/html/quasonix/hypertrack/hypertrack_software-instruction-manual_3539179031.webp)
HyperTrack™
Software Instruction
22
Quasonix, Inc.
In the example in Figure 19, the Active Channel is
not selected, so the logger only records the selected
tracking channels highlighted green.
In this example, the green channels are Channel 1-
LHCP, Channel 2-RHCP, and Channel 3-COMB.
Selected data for these three channels is recorded.
Tracking data is always present on all track
channels, even if they are not in use for tracking a
target (there must be an AM / AGC connection to a
receiver for each channel).
Figure 19: Log Settings
—
Three
Channels Selected
When selected, the logger feature also captures the following parameters: Status Flags, Fault Flags, and Track Flags.
Selectable parameter abbreviations are listed in Table 3 and Table. If a fault condition appears, while the logger is
enabled and the fault is present in the Fault Flags list, the abbreviated flag is recorded and displays in the resulting
saved log file, as long as a flag(s) parameter is selected and is highlighted green.
Table 3: System General Fault Tags
SFE
Safe Switch is enabled
STW
Stow Pin not in sensor receptacle
SHT
Shorting Plug is not installed
EIF
External Interlock Fault (Interlock Box is unplugged or active)
SCF
Safety Controller Fault ( Safety Controller in the servo assembly is faulting)
ECF
EtherCAT disabled fault ( EtherCat line is unplugged or switch has failed)
FCF
Feed Controller Fault (fault within the yoke arm mounted feed control box)