NewFEIMAS
Refer to Revision Record on page 2.
T.Anzai
Nov. 20, 2008
K.Okada
Rev
04
03
PAGE
58
/
138
PFU LIMITED
P1PA03334-B30X/6
Refer to Revision Record on page 2.
T.Anzai
July 7, 2008
K.Okada
Refer to Revision Record on page 2.
K.Okada
K.Okada
DESCRIPTION
CHECK
DATE
T.Anzai
APPR.
K.Okada
K.Okada
Aug.19, 2005
DESIG
N
DESIG
.
CUST.
I.Fujioka
I.Fujioka
T.Anzai
CHECK
fi-5530C/fi-5530C2
IMAGE SCANNER
MAINTENANCE MANUAL
APPR.
TITLE
DRAW.
No.
Feb.23, 2007
05
Section 3-3-20
3-3-20. “E9: Image memory alarm”
Table 3-3-20
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Replace the Control PCA and see if the
error is resolved.
Refer to
Section 4-11
for replacement.
3-3-21. “EA: Imprinter error”
Table 3-3-21
Item
No.
Check items
How/where to check
1
Is Print cartridge attached correctly?
Attach the cartridge correctly.
(Refer to Section 2-3 in Imprinter maintenance manual.)
2
Replace the Print cartridge. Is the alarm
resolved?
Refer to Section 3-3 in the Imprinter maintenance manual.
3
Is the cable from imprinter (EXT cable)
connected correctly?
Refer to Section 2-2 in the Imprinter maintenance manual.
4
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
5
Replace the Control PCA. Is the error
removed after replacing Control PCA?
Refer to Section 5-4 in the Imprinter maintenance manual.
3-3-22. “Ec: RAM alarm”
Table 3-3-22
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Replace the Control PCA and see if the
error is resolved.
Refer to
Section 4-11
for replacement.
3-3-23. “Ed: SPC alarm”
Table 3-3-23
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Replace the Control PCA and see if the
error is resolved.
Refer to
Section 4-11
for replacement.