5-1-8 Maintenance mode #7: EEPROM data restore
When replacing the Panel PCA, the EEPROM data on the Panel PCA shall be moved to the flash memory of the Control PCA.
In this mode, the data is restored from the Control PCA to the Panel PCA.
[How to start]
(1) Select (Maintenance mode #7) by pressing Function button at Screen T04, and then press Scan button. The following
display appears.
Screen T71
Function No.
Display
Scanner status
“o” (down half) blinks.
Confirming whether the data shall be restored or
not.
<Available buttons at Screen T71>
Scan
+ Function button: Returns the data from the Control PCA to the EEPROM on the Panel PCA. During restoring
operation, Screen T72 is displayed. If the data restore terminates normally, Screen T73
appears. If no data exists in the Control PCA, Screen T74 appears.
Send to button: Terminates this mode and returns to Screen T04.
Screen T72
Function No.
Display
Scanner status
“L” (upper half) lights without blinking.
The data is being restored.
Note: While Screen T72 is displayed, no button can function.
Screen T73
Function No.
Display
Scanner status
Displays “o” (upper half) without blinking.
The data has restored normally.
<Available buttons at Screen T73>
Send to button: Terminates this mode and returns to Screen T04.
Screen T74
Function No.
Display
Scanner status
Displays
“c”
without
blinking.
No data exists in the Control PCA.
<Available buttons at Screen T74>
Send to button: Terminates this mode and returns to Screen T04.