4-9-6. Replacing the LF Motor
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-16
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear cover and Upper cover by referring to Sections from
4-7-1
to
4-7-5
.
(2) Remove the cable from LF Motor from the hole of Chassis. Also remove the cable from two cable clamps and all hooks.
Then remove two screws from the LF Motor and detach the LF Motor.
<Mounting>
Follow the removing procedure in reverse. Confirm that the cables are routed as shown in above figures.
When securing the screws of the motor, pull the motor up to apply the belt tension so that the tension becomes the value
shown in the following figure.
650±50g
LF Motor
Cable of LF Motor
Cable clamp
Two screws
A hole of chassis