Section 4-10-7
4-10-7. Replacing the Pick Motor
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-11
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear cover, Upper cover and Guide A ASSY by
referring to Sections from
4-7-1
to
4-7-6
.
(2) Remove the Dust cover by referring to
Section 4-10-3
.
(3) Remove two motor cables that run on the backside of the
scanner from a hole of chassis and all hooks.
(4) Remove two screws from PICK Motor, and remove the motor.
Reference: PICK Motor includes the cable, gears and bracket
with shafts.
<Mounting>
Follow the removing procedure in reverse.
(1) Align the shaft and tab of the bracket with the slot and square
hole of the frame respectively.
(2) When routing the motor cable on backside of the scanner,
insert thinner cable first to avoid cables come out the hooks.
Two screws
PICK Motor
Shaft
Tab of bracket
Cables for motors
Hole of chassis
Cables for motors
Hole of chassis