Section 4-10-5
4-10-5. Replacing the Lamp SR (for ADF front)
As the dust-proof area in the scanner is opened by the following procedure, do not replace the following parts in a dusty
room.
Refer to
Section 6-5
for the part number of the replacement part.
<Removing>
(1) Remove Chute unit (ADF paper chute), Stacker unit, PCB unit, Rear cover, Upper cover and Guide A ASSY by
referring to Sections from
4-7-1
to
4-7-6
.
(2) Remove the Dust cover by referring to
Section 4-10-3
.
(3) Loosen two screws, and remove the
Black sheet from Dust cover.
(4) Release three craws A that fix the Reflector of the lamp.
(5) Remove the Lamp SR form the Reflector.
<Mounting>
(1) Follow the removing procedure in reverse. If the glass of the Dust cover and the inside of the reflector are dirty, clean
them.
(2) Take care that the cables are routed as follows.
(3) After mounting the Lamp, perform the following adjustment:
■ White balance adjustment (
Section 5-1-5
)
■ Offset adjustment (
Section 5-1-4
)
■ Magnification adjustment (
Section 5-1-3
)
Slim cable shall be
under the thick cable
Craw A (3 locations)
Claw A
Screw fixing Black sheet