Section 1-7-1
1-7 Daily Care
This section describes how to clean each part of the scanner.
WARNING
The glass surface inside the ADF becomes hot during the operation of the scanner. Before you start to clean the inner parts
of the scanner, disconnect the AC adapter from the power outlet, and wait at least 15 minutes.
Do not turn off the scanner when you clean the Feed Rollers and Eject rollers.
Clean the ADF after every 5,000 scans. Without periodical cleaning, document feeding or transportation may be troubled.
The scanner must be cleaned more frequently if you scan any of the following type of sheets:
- Documents of coated paper
- Documents that are almost completely covered with printed text or graphics
- Chemically treated documents such as carbonless paper
- Documents containing a large amount of calcium carbonate
- Documents written by pencil
- Documents on which the toner is not fused sufficiently
1-7-1 Cleaning ADF
1. Open the ADF while pushing down the ADF button.
Caution: Be careful, the ADF cover may close and pinch your fingers.
2. Clean the following locations with a lint-free
cloth moistened with ethyl alcohol isopropyl
alcohol.