PACIO-400-02 - Extender 2 Port
The purpose of the PACIO Extender 2 Port Module is the extension of a PACIO block.
Technical Data
PACIO Extender 2 Port
Part number
PACIO-400-02
Controller
ASIC ET1200
Baud rate
100Mbit/s
Cable
CAT5
Cable length
Maximum 100m (328 feet)
EtherCAT connection
2 x RJ45
Power supply
via E-Bus
E-Bus load
160mA for Out1 / 210 mA for Out1+Out2
Terminals
Supply to the Module: via E-Bus
EtherCAT
OUT1
RJ45-Socket
Output port (to the next EtherCAT-device)
OUT2
RJ45-Socket
Output port (to the next EtherCAT-device)