D-17
Parameter Reference
AC30V series Variable Speed Drive
PNO Parameter Descriptions
Clone Status
This parameter indicates the status of the cloning process.
Enumerated Value : Power Parameters
0 : IDLE
- waiting for the user to start the cloning process.
1: SAVING
- in the process of saving the drive configuration to file.
2 : RESTORING
- in the process of loading the configuration from file.
3 : VERIFYING
- in the process of verifying the clone file either before a load or after a save.
4 : DONE
- the cloning process has completed successfully either for a load or a save.
5 : CANNOT START
- the cloning process cannot start. When restoring a configuration the drive must be stopped.
6 : FAILED
- general failure of the cloning process.
7 : NO SD CARD
- no SD card is fitted.
8 : VERIFY FAILED
- the verifying process of the clone file has failed. E.g. the file is corrupt.
9 : FILE NOT OPENED
- cannot open the clone file. E.g. for a save the file is write protected; for a load the file does
not exist.
10 : FILE INCOMPATIBLE
- the file format is not compatible. E.g. the file is not a clone file.
11 : FILE FAILURE
- reading from or writing to the file fail. E.g. the SD card was removed during a load or save.
12 : POWER MISMATCH
- the clone file was saved on a drive with a different power stack. See parameter description
notes above for
1538 Full Restore
and
1541 Power Parameters
.
13 : APPLICATION FAILURE - could not restore the application. E.g. the application is missing from the clone file.
14 : PARAMETERS FAILURE - could not restore the parameters. E.g. the parameters are missing from the clone file.
Notes:
1) The clone file only contains the parameters that were stored in non-volatile memory on the drive when a clone save was performed. When
performing a clone load and a full restore is performed or a LOAD FROM FILE is used for the parameters, then any parameter not previously
saved in the file will be set to its defaults.
2) Each application parameter is restored only if the parameter definition on the target drive matches the saved parameter.
3) The clone saving process will take between 3 – 15 seconds depending on the type of SD card used.
4) When saving a file with the same filename as an existing file on the SD card, the existing file will be overwritten. To prevent this, use a PC to
set the read-only attribute of the file.
5) During the clone loading process the GKP screen may blank momentarily.