D-87
Parameter Reference
AC30V series Variable Speed Drive
Raise Lower
Setup::Application::Raise Lower
Monitor::Application::Raise Lower*
Appears when the
Raise/Lower
macro is selected.
The
Raise/Lower
function acts as an internal motorised potentiometer (MOP) used as a reference source.
PNO Parameter Descriptions
RL Ramp Time
Rate of change of the
Output
. Defined as the time to change from 0.00% to 100.00% . Note that the raise and lower rates are
always the same.
RL Reset Value
The value
Output
is set to when the
Reset Input
is TRUE.
RL Maximum Value
The maximum value to which
Output
will ramp up to.
RL Minimum value
The minimum value to which
Output
will ramp down to.
Reset Input
This is connected to a Digital Input as part of the selected Macro. When TRUE forces
Output
to track
Reset Value
.
Raise Input
This is connected to a Digital Input as part of the selected Macro. When TRUE causes
Output
to ramp up.
Lower Input
This is connected to a Digital Input as part of the selected Macro. When TRUE causes
Output
to ramp down.
Raise Lower Output*
The ramp output monitor.
Output
is preserved during the power-down of the Drive.