Installation
4-5
AC30V Variable Speed Drive
Frame
D
Through panel
cut out detail.
Frame
E
Through panel
cut out detail.
Typical Panel
Typical Panel
Through Panel Mount Frames D to J only
DIMENSIONS FOR THROUGH PANEL INSTALLATION
FRAMES D, E
Through panel mounting a drive in a cubicle allows you to use a smaller cubicle because much of the heat generated by the drive is dissipated
outside the cubicle.
Figure 4-4 Mechanical Dimensions for Through Panel Frames D & E AC30V Drive
Models
H
H1
H2
W
W1
W2
W3
D
D1
Fixings
Mounting Kits
Frame D
250 (9.8)
262 (10.3)
6 (0.2)
79 (3.1)
1.5 (0.06)
82 (3.2)
100 (3.93)
72 (2.8)
181 (7.1)
Use M4
fixings
LA502668
Frame E
297 (11.7)
309 (12.1)
6 (0.2)
104 (4.1)
1 (0.04)
102 (4)
125 (4.9)
72 (2.8)
181 (7.1)
LA502669
All dimensions are in millimetres (inches)