Setup Wizard
9-9
AC30V series Variable Speed Drive
Set Up PMAC Motor Control
Minimum steps ( and list of parameters ) for setting a PMAC motor control are given below :
0511 Motor Type
0555 PMAC Max Speed
0556 PMAC Max Current
0557 PMAC Rated Current
0558 PMAC Rated Torque
0559 PMAC Motor Poles
0564 PMAC Motor Inertia
1387 PMAC Base Volt
Enter basic motor
parameters
0560 PMAC Back Emf Const KE
0561 PMAC Winding Resistance
0562 PMAC Winding Inductance
0563 PMAC Torque Const KT
0464 100% Speed in RPM
0478 PMAC SVC Start Cur
0479 PMAC SVC Start Speed
Speed unstable ?
0486 Acceleration Time
0487 DecelerationTime
1257 Seq Stop Method SVC
Motion too smooth ?
Reduce speed loop bandwidth
Increase speed loop bandwidth
1247 Ratio Load Mot Inertia
01248 Speed Loop Bandwidth
Y
Y
Y
Set Acceleration –
Deceleration rate
Choose Stopping mode
Enter 100% speed setpoint
Run Auto-tune ?
Y
N
Motor models parameters
identified by autotune
Enter Motor models
parameters from datasheet
1st motor run
Set SVC PMAC
PMAC Control Selected?
End of minimum settings
Select stack
overload capability
0390 Duty Selection
/Motor Control/Control Mode
/Motor Control / PMAC Motor Data
/Motor Control /Scale Setpoint
/Motor Control /Ramp
/Motor Control /Ramp
/Motor Control /PMAC SVC
/Motor Control / PMAC Motor Data
/Motor Control / Feedbacks
/Motor Control / PMAC Motor Data
0564 PMAC Motor Inertia
/Motor Control / Spd Loop Settings
/Motor Control/Control & Type
/Motor Control/Motor Data PMAC
/Motor Control/Motor Data PMAC
/Motor Control/Motor Data PMAC
/Motor Control/Control & Type
/Motor Control/Control & Type
/Motor Control/SVC PMAC
/Motor Control/Control & Type
/Motor Control/Control & Type
OR
OR
OR
OR
OR
OR
OR
OR
OR
Setup Menu
Parameters Menu ( if (1141 View Level = Engineer) )
Parameters