background image

tams elektronik

Manual

4-fold Turnout Decoders

WD-34.BiDiB

Item no.
46-12356 | 46-12357

WD-34.M.BiDiB

Item no.

46-12366 | 43-12367

t

a

ms elektronik

n n n

Summary of Contents for 43-12367

Page 1: ...t a m s e l e k t r o n i k Manual 4 fold Turnout Decoders WD 34 BiDiB Item no 46 12356 46 12357 WD 34 M BiDiB Item no 46 12366 43 12367 tams elektronik n n n ...

Page 2: ... Elektronik GmbH All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying without prior permission in writing from Tams Elektronik GmbH Subject to technical modification Page 2 ...

Page 3: ...ment in the BiDiBus system addressing 12 4 Technical specifications 13 5 Connecting the decoder 15 5 1 Pin connections WD 34 BiDiB 16 5 2 Pin connections WD 34 M BiDiB 17 5 3 Power supply 19 5 4 Connection examples 20 5 5 Connection to the BiDiBus 21 6 Settings 22 6 1 Identify button 22 6 2 Firmware update and configuration 22 7 Check list for troubleshooting 24 8 Guarantee bond 26 9 EU declaratio...

Page 4: ...on Before you start we advise you to read the whole manual particularly the chapter on safety instructions and the checklist for trouble shooting You will then know where to take care and how to prevent mistakes which take a lot of effort to correct Keep this manual safely so that you can solve problems in the future If you pass the decoder on to another person please pass on the manual with it In...

Page 5: ...46 12357 or 46 12368 an Ethernet patch cable with RJ 45 connectors length 0 5 m two short circuit jumpers a CD containing the manual and further information Required materials In order to connect the module you need wire Recommended cross sections 0 25 mm for all connections WD 34 BiDiB only When using motor run turnouts you need an additional adapter AMW 1 or AMW plus for each turnout item no 72 ...

Page 6: ...ew ones Electrical hazards Touching powered live components touching conducting components which are live due to malfunction short circuits and connecting the circuit to another voltage than specified impermissibly high humidity and condensation build up can cause serious injury due to electrical shock Take the following precautions to prevent this danger Never perform wiring on a powered module A...

Page 7: ...odule Other dangers Children can cause any of the accidents mentioned above because they are inattentive and not responsible enough Children under the age of 14 should not be allowed to mount this module In schools training centres clubs and workshops assembly must be supervised by qualified personnel In industrial institutions health and safety regulations applying to electronic work must be adhe...

Page 8: ... The decoders WD 34 BiDiB and WD 34 M BiDiB are designed to control accessories activated by a short switching impulse Since the switching time can be set as required both accessories with as without tape shut off can be connected Examples of use WD 34 BiDiB WD 34 M BiDiB Solenoid accessories Coil driven turnouts X X Semaphore signals with twin coil drive X X Decouplers X X Motor driven turnouts A...

Page 9: ... points decoder WD 34 BiDiB has the following optional features Monitoring and spontaneous message WD 34 BiDiB only In combination with points with limit stop the points decoder WD 34 BiDiB can identify and report the actual position of points In case the points are set by hand or mechanical problems occur during operation the decoder sends an automatic message to the PC With the decoder WD 34 BiD...

Page 10: ...extend the structure by an additional level Example for a BiDiB controlled layout part The interface ZEUS provides the connection between PC control and the nodes on the different levels of the system The example shows different turnout decoders in the highest level switching for example coil driven points WD 34 BiDiB and motor driven points WD 34 M BiDiB The hub ARTEMIS provides an additional lev...

Page 11: ...t a m s e l e k t r o n i k WD 34 BiDiB WD 34 M BiDiB English Page 11 ...

Page 12: ...for the automatic assignment the turnout decoder has a unique number unique ID programmed by the manufacturer When switching on the BiDiB system the interface scans the present nodes within its structure and makes a list with the available nodes their unique IDs and a local address valid for this session only With a new node connected to the bus the list of the present nodes is upgraded automatica...

Page 13: ...the actual position of points with points with limit stop spontaneous message if the position of points is different Status of the BiDiB specification V0 7 Supply voltage 12 18 V a c voltage or 14 24 V d c voltage Current consumption without connected devices approx 60 mA Number of outputs 8 Max total current 3 000 mA Max current per output up to 2 seconds 1 500 mA persistent 800 mA Protected to I...

Page 14: ...nglish WD 34 BiDiB WD 34 M BiDiB Dimensions of the PCB including housing approx 72 x 82 mm approx 100 x 90 x 35 mm Weight of the assembled board including housing WD 34 BiDiB approx 45 g 93 g WD 34 M BiDiB approx 49 g 97 g Page 14 ...

Page 15: ...w on the connecting wires for turnouts and or solenoid accessories and the power supply On the other side the decoder has two RJ 45 connection sockets for the connection to the BiDiBus Figure WD 34 BiDiB Make the connections one after the other the turnouts and or solenoid accessories the interface and or other nodes on the same level the power supply Page 15 ...

Page 16: ...ccessory turnout 3 return conductor 6 Solenoid accessory turnout 3 straight 7 not in use 8 Power supply 12 18 V or 14 24 V 9 not in use 10 Solenoid accessory turnout 2 diverging 11 Solenoid accessory turnout 2 return conductor 12 Solenoid accessory turnout 2 straight 13 Solenoid accessory turnout 4 diverging 14 Solenoid accessory turnout 4 return conductor 15 Solenoid accessory turnout 4 straight ...

Page 17: ...iverging 2 not in use Solenoid accessory turnout 1 return conductor 3 Motor run turnout 1 connection 2 Solenoid accessory turnout 1 straight 4 Motor run turnout 3 connection 1 Solenoid accessory turnout 3 diverging 5 not in use Solenoid accessory turnout 3 return conductor 6 Motor run turnout 3 connection 2 Solenoid accessory turnout 3 straight 7 not in use 8 Power supply 12 18 V or 14 24 V 9 Inpu...

Page 18: ...id accessory turnout 2 return conductor 12 Motor run turnout 2 connection 2 Solenoid accessory turnout 2 straight 13 Motor run turnout 4 connection 1 Solenoid accessory turnout 4 diverging 14 not in use Solenoid accessory turnout 4 return conductor 15 Motor run turnout 4 connection 2 Solenoid accessory turnout 4 straight 16 not in use 17 Power supply 12 18 V or 14 24 V 18 not in use RJ45 BiDiBus c...

Page 19: ...with digital control unit to the power supply used to supply BiDiB nodes When connecting a node to the power supply the polarity is of no importance In case several similarly designed decoders e g WD 34 M BiDiB SD 34 BiDiB or MD 2 BiDiB are connected to the same power supply the assignment of ground plus of the transformer or plus minus of the power pack should be the same with all decoders Cautio...

Page 20: ...i k English WD 34 BiDiB WD 34 M BiDiB 5 4 Connection examples Connecting coil driven turnouts Connection of points to terminals 13 to 15 points 4 Connecting decouplers Connection of two decouplers to terminals 13 to 15 Page 20 ...

Page 21: ...wo RJ 45 connection sockets are connected in parallel and thus can be used optionally for the connection of the decoder to the BiDiB interface and or other BiDiB nodes on the same level In case the WD 34 M BiDiB is the last node in a level you have to bypass the two 2 pole socket pins beside the RJ 45 connection sockets The easiest way is to insert the jumpers included in the scope of supply Page ...

Page 22: ... display of the control software you have to push the identify button on the PCB Then the assigned BiDiB node is highlighted in the screen display and the LED on the decoder flashes 6 2 Firmware update and configuration By means of the applicactions BiDiB Wizard and BiDiB Monitor both available as free downloads you can perform a firmware update and configurate the decoder Please check the descrip...

Page 23: ...e of the delivery the function is switched on for use with points with limit stop If points without limit stop are connected the function has to be switched off On Time The settings are made individually for each of the 4 points each pair of outputs The on time can be set to a time between 100 msec and 127 sec individually for each of the 4 points each pair of outputs Value in state of the deliver...

Page 24: ...d Possible cause The patch cable s is are incorrectly inserted into the connection sockets or is are defective à Check the cable s and the connection s Possible cause The interface s connection is faulty or the interface is defective à Check the interface and the connections Check whether other nodes connected to this interface are also not displayed Connected accessories do not switch Possible ca...

Page 25: ...rantee the maximum fee for the repair is 50 of the current sales price according to our valid price list We reserve the right to reject the repairing of a module when the repair is impossible for technical or economic reasons Please do not send in decoders for repair charged to us In case of warranty we will reimburse the forwarding expenses up to the flat rate we charge according to our valid pri...

Page 26: ...ss and quality of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and the ready built circuit connected according to the manual and when start and mode of operation follow the instructions We retain the right to repair make improvements to deliver spares o...

Page 27: ...t installed by an authorised electrician Make no changes to the original parts and accurately follow the instructions connection diagrams and PCB layout included with this manual Use only original spare parts for repairs 2011 65 EG on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS Underlying standard EN 50581 10 Declarations conforming to the...

Page 28: ...n n Information and tips n n http www tams online de n n n Warranty and service n n Tams Elektronik GmbH n Fuhrberger Straße 4 DE 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de n n n n ...

Reviews: