D-23
Parameter Reference
AC30V series Variable Speed Drive
Current Loop
Setup:: Motor Control::Control & Type:: Motor Type
Parameters::Motor Control::Control Loop
PNO
Parameter Descriptions
Enable Predict Term
To enable the predictive term of the current loop.
Functional Description
This is to add the predictive term into the voltage demand formulated by the current regulator so to to increase the dynamic performance of
motor drive. It is recommented to enable this parameter if the permanent magnet motor is used