D-15
Parameter Reference
AC30V series Variable Speed Drive
PNO Parameter Descriptions
Full Restore
If the parameter
1537 Clone Direction
is set to LOAD FROM FILE, then the parameter
Full Restore
determines if a full restore or a
partial restore is required from the file specified.
If YES is chosen then all the saved parameters and the saved application will be loaded including ‘drive unique’ parameters.
If PARTIAL is chosen then the user has the choice of what to restore, however ‘drive unique’ parameters will keep their current
values. The following clone parameters apply:
1539 Application
1541 Power Parameters
1540 Other parameters
Notes:
-
If the power stack of the drive is different to the power stack from which the clone file was saved and the user chooses YES then
the clone load will not be permitted. However the clone load will be permitted if the control module on which the user is restoring
is not attached to a power stack, or if PARTIAL is chosen instead.
-
The power parameters cannot be restored from a clone file that was saved on a control module with the parameter
0989 Power
Stack Required
set to NONE.
Enumerated Value : Full Restore
0 : YES
1 : PARTIAL
Application
If the parameter
1538 Full Restore
is set to PARTIAL, then the parameter
Application
allows the user to either load the application
from the file or to leave the currently installed application.
Enumerated Value : Application
0 : LOAD FROM FILE
1 : LEAVE CURRENT APP