D-37
Parameter Reference
AC30V series Variable Speed Drive
PNO Parameter Descriptions
iq
Current in the torque axis (Vector Control)
Actual Torque
Calculated torque, based on the Iq current.
Actual Field Current
Calculated field, based on the Id current.
Motor Current Percent
This diagnostic shows the level of rms line current being drawn from the drive as a percentage of the rated current of the relevant
motor definition.
Motor Current
This diagnostic shows the level of rms line current in Amps being drawn from the Drive.
100% Stack Current A
This diagnostic indicates the stack rating in Amps. This reduces as a function of pwm switching frequency.
Stack Current (%)
Stack current percentage.
Motor Terminal Volts
Volts between motor phases in Vrms.
CMTemperature
Temperature of Control Module in
o
Centigrade.
Heatsink Temperature
Power stack heatsink temperature in
o
Centigrade.
Elec Rotor Speed
Mechanical speed (shaft speed in
rev
/
s
) x number of motor pole pairs. This parameter is not filtered.
Heatsink OT Trip
Heatsink Overtemp Trip Level.
Heatsink OT Warning
Heatsink Overtemp Warning level.
Heatsink Hot Warning
Heatsink Hot Warning Level.