Installation
4-21
AC30V Variable Speed Drive
APPLICATION 0: BASIC SPEED CONTROL
RELAY 01
(X14/01)
(X14/02)
RELAY 02
(X14/03)
(X14/04)
ANIN 01 (X11/01)
ANIN 02 (X11/02)
FWD / REV
REFERENCE SELECT
0501
Jog Setpoint
RAMP
0486
Acceleration Time
MIN /MAX SPEED
1264
Ref Min Speed Clamp
1265
Ref Max Speed Clamp
SPEED SETPOINT
SPEED TRIM
RUNNING
NOT TRIPPED
CURRENT LIMIT
V/F SHAPING
CT
VT
V
F
PWM CONTROL
I FDBK
F
V
F
V
0484
Seq Stop Method
DIGIN 01
(X13/02)
DIGIN 02
(X13/03)
DIGIN 03
(X13/04)
DIGIN 04
(X12/01)
DIGIN 05
(X12/02)
DIGIN 06
(X12/03)
DIGIN 07
(X12/04)
SEQUENCING LOGIC
RUN
JOG
NOT STOP
NOT COAST STOP
NOT QUICKSTOP
TRIP RESET
REVERSE
0422
Vhz Shape
0457
Base Frequency
0447
Fixed Boost
0455
Rated Motor Current
FEEDBACKS
ANOUT 01
(X11/03
)
ANOUT 02
(X11/04)
SPEED DEMAND
MOTOR CURRENT
Application 0:
“Basic Speed Control”
IDEAL FOR GENERAL PURPOSE APPLICATIONS,
NORMAL DUTY AND HEAVY DUTY
Speed
0487
Deceleration Time
0504
Stop Ramp Time
0508
Quickstop Ramp Time