Compliance
C-36
AC30V series Variable Speed Drive
CANADIAN COMPLIANCE
This product has been approved by Intertek Testing and Certification Ltd (ETL) to Canadian Standard CSA 22.2 No. 14, Standard for Industrial
Control Equipment and Canadian Standard CSA 22.2 No. 14, Industrial control Equipment.
NORTH AMERICAN AND CANADIAN COMPLIANCE INFORMATION
Motor Base Frequency
PMAC and Induction motor modes are identical.
Drive Switching Frequency Maximum Output Frequency
4 kHz
500Hz
8 kHz
590Hz (1000Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
12 kHz
590Hz (1500Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
16 kHz
590Hz (1500Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
Drive Protection
Branch Circuit Protection
It is recommended that UL Listed non-renewable cartridge fuses (JDDZ) or UL Listed renewable cartridge fuses (JDRX) are installed upstream of
the drive. Refer to Appendix F: “Technical Specifications” - Power Details for recommended fuse ratings.
Solid-State Motor Overload Protection
This product provides Class 10 motor overload protection. The maximum internal overload protection level (current limit) is 180% for 3 seconds,
in addition Heavy Duty mode is 150% for 60 seconds and Normal Duty mode is 110% for 60s in. Refer to Appendix D Programming –
Current
Limit
for user current limit adjustment information.
An external motor overload protective device must be provided by the installer where the motor has a full-load Ampere rating of less than 50% of
the drive output rating or when the
Disable Stall
trip is enabled; or when the
Stall time
parameter is increased above 480 seconds (refer to
Appendix D Programming :
Stall Trip
).
Motor over temperature sensing is not provided by the product unless the external temperature sensor is connected to the motor thermistor input
on the GPIO option. When the GPIO option is not fitted an external motor over temperature device is required.